Dennison Chimney Works

A Pellet Stove That Starts, Feeds and Heats as It Should

Ask About This Job

Where Dennison Starts

Pellet stoves are machines that happen to burn, so faults usually trace to a motor, a sensor or a dirty passage. We strip out the ash, clean the exhaust path, test the feed motor, igniter, fans and switches, and replace whatever fails a reading. If the stove sits on a hearth we are remodeling, we also confirm its pad and wall gaps. Service across Maywood.

Ash and fly ash stripped from the passages
Feed motor and igniter tested under load
Room and exhaust fans cleaned
Safety switches read with a meter
Hearth pad and wall gaps confirmed

How a Pellet Stove Fails

Pellets sit in a bin on top of or behind the stove. A slow screw at the base of the bin drops a measured amount into a small cup, where an electric element lights them. One fan draws the exhaust out through the vent; another blows room air across the hot box and back into the room. Switches and temperature sensors tell the controller whether the vent is clear, whether the fire caught and whether the stove is overheating, and the controller stops everything the moment one of them disagrees. That is why a pellet stove can quit for a dozen reasons: a jammed screw, a burnt-out element, a dirty cup that will not hold a flame, a tired fan, a blocked vent, a pressure switch with a split hose, a sensor knocked out of position or damp pellets that crumble to dust. Each one ends in the same cold stove, and only testing tells them apart.

We start with the stove's own record. Most controllers show a code or a pattern of lights when they shut down, and that narrows the search. Then we clean, because ash in the cup, the heat exchanger and the vent is a common cause of shutdowns, and a stove that is properly clean often runs again with no new part at all. After that we test the feed motor, the element, the fans and the switches one at a time and replace only what fails, using parts listed for that model. The vent pipe is checked for joints that leak and for an outside cap clogged with ash or a nest. The seals on the door and the ash pan are checked too, because a leaking door lets in air the controller did not expect, and that alone can make a stove burn badly or shut itself off partway through the evening.

Booking and Price

Pellet stove repairs are priced after diagnosis, since a feed motor and a control board sit far apart in cost. The visit tells us which part has failed, and you get a written price for the part and the labor before we order or fit it. When you book, describe what happens when the stove stops: whether it lights at all, how long it runs and whether smoke or a code appears. Make sure the stove is off and cool for the visit, and keep a bag of the pellets you burn nearby, since pellet quality is sometimes the whole answer. Damp storage, a bag with a lot of dust in it or a change of brand can make a healthy stove choke its cup in a day. If that turns out to be the cause, we tell you, clean the stove and leave the parts alone, and the visit costs far less than a repair would.

Pellet stoves are less common in Maywood than in the mountain towns, but where one sits in a living room it is usually the main heat source, and its looks matter as much as its output. A stove with a smoky glass door, a dull finish or a rusty top makes a poor centerpiece. While it is apart, we clean the glass, check the door seal and note anything worn on the outside, and if the stove has reached the end of its working life, we can talk about a gas insert or a freestanding stove that suits the room better. We service pellet stoves across Maywood, Norwalk and Los Angeles. If yours sits on a hearth pad or against a wall finish that no longer suits the room, the same visit can start a conversation about a new pad or a tiled wall behind the stove.

Habits on Every Dennison Job

Look Inside First

Firebox, damper and flue seen before any plan

Measured Wall

Opening, hearth and mantel height taped

Itemized Scope

Each finish and repair on a separate line

Room Left Clean

Floors covered and dust kept to the hearth

More Hearth and Chimney Work

Chimney Sweep

Soot and tar scraped from the flue so a new insert, a fresh surround or next winter's fires start on a clean draft.

Details →

Chimney Inspection

A look at the firebox, flue, crown and cap before you spend money on a new hearth, a mantel or an insert.

Details →

Chimney Repair

Cracked brick, failed joints and leaking tops on the stack fixed so the room below can be finished without water stains.

Details →

Fireplace Inspection

The firebox, damper, hearth and the space around the opening measured and judged before a refacing or a new mantel goes in.

Details →

Fireplace Repair

Cracked firebrick, loose panels, a sticking damper or a crumbling hearth set right, so the fireplace works as well as it looks.

Details →

Chimney Level 2 Inspection

A camera pass from firebox to crown, with attic and roof checks, before a sale, a fuel change or a new insert.

Details →

Chimney Cap Installation

A stainless or copper top fitted over the flue to keep rain, nesting birds and stray sparks where they belong.

Details →

Chimney Flashing Repair

New metal laid where brick meets shingles, so the ceiling beside your new mantel stays dry through the winter storms.

Details →

Chimney Masonry Repair

Weathered brick faces and sandy joints rebuilt with mortar and brick chosen to match the color of the stack.

Details →

Chimney Rebuilds

A stack that leans, cracks through or pulls from the wall taken down and laid back up in brick that suits the house.

Details →

Fireplace Cleaning

Ash, soot and smoke shadows taken off the firebox, the face and the hearth so stone, tile or brick shows its real color.

Details →

Gas Fireplace Cleaning

Burner, glass and log set cleaned on a gas unit so the flame stands tall and blue against the new surround.

Details →

Gas Fireplace Repair

A gas unit that refuses to light, drops out or burns weak, traced to the failing part and brought back.

Details →

Fireplace Remodel

A dated fireplace wall rethought from floor to ceiling: new face, mantel and hearth, with the fire's clearances designed in.

Details →

Fireplace Inserts

A sealed gas or wood firebox set into the old opening, with a new liner and a face that suits the room.

Details →

Wood Stove Repair

A freestanding stove's door seals, glass, baffle and stovepipe restored so it burns clean on a hearth that fits it.

Details →

Gas Logs

Ceramic logs and a burner chosen for the look you want, fitted to the opening and lit before we leave.

Details →

Chimney Seismic Retrofit

Older brick chimneys anchored to the house or lightened above the roof so a strong quake is less likely to drop them.

Details →

Chimney Crown Repair

A sloped concrete top recast or sealed over the brick, so rain runs off instead of soaking in.

Details →

Dryer Vent Cleaning

Lint packed in the dryer duct cleared from the laundry to the outside hood, so loads dry faster and the duct runs cooler.

Details →

Chimney Liner Installation

A stainless liner run inside the old flue so an insert, a gas conversion or a cracked tile flue vents safely.

Details →

Chimney Leak Repair

A damp chimney breast or a stain beside the mantel traced to where the water enters, then sealed there.

Details →

Chimney Waterproofing

A breathable water repellent soaked into clean brick so rain beads off and the fireplace wall inside stays dry.

Details →

Chimney Damper Repair

A damper that sticks, rattles or lets winter air pour in, freed, rebuilt or swapped for a lid at the crown.