A fireplace in every unit, and a record for each one

Plan a building visit

The safety items, in the order we check them

Every unit gets the same list, so a manager can compare one apartment with the next and spot the outlier.

  • Carbon monoxide: a meter reading near the fireplace with it running, where it can be run, and a note on whether an alarm is mounted in the unit.
  • Draft: does smoke or exhaust go up, or roll back into the room?
  • Gas: the shutoff valve reachable and closing, the pilot steady, the glass whole and sealed.
  • Wood: the damper opening fully, the firebrick sound, the flue clear of soot and nests.
  • The room side: a screen or doors in place, a hearth deep enough, nothing that burns stacked close to the opening.

Why carbon monoxide comes first

Carbon monoxide has no smell and no color. A gas fireplace with a blocked vent, a cracked glass seal or a damper clamp missing from a log set can push it into a living room while looking perfectly normal. Tenants sit close to a fireplace for hours, often in the evening and often with windows shut. That is why the meter comes out before anything else, and why a reading out of line stops the check for that unit until the cause is found.

California expects homes with a fuel burning appliance or a fireplace to have a carbon monoxide alarm. We note on each page whether one is there and working at the time of the visit; the alarm itself is the owner's to fit or replace.

What a manager receives

Each unit gets a page with its number, the date, the fuel, the meter reading and a verdict: fit for use, fix soon, or shut down until repaired. Any fireplace marked shut down is listed at the top of the summary so it can be dealt with before the next cold evening. The pages are plain enough to file with a lease, hand to an insurer or show a board.

Where the visual check raises a question it cannot answer, such as a flue that will not draw or smoke stains above a gas unit, we say which unit needs the camera inspection and why, rather than putting a camera in every flue by default.

Per fireplace pricing

Each fireplace on the property is checked and charged on its own, so a building with six fireplaces gets six pages and six lines on the invoice.

Safety check, per fireplace
$56
Camera follow up where a unit needs one
$405
Sweeping a wood flue that is caked
from $430

Gas valves, pilots or glass that need parts get a written figure for that unit alone.

Managers and boards ask

How often should rental fireplaces be checked?

Once a year before the cool months suits most buildings, and again whenever a tenant reports smoke in the room, a smell of gas or a pilot that keeps going out.

What happens if a unit is marked shut down?

We tell the manager on the day, explain why on the unit page, and suggest the tenant does not use the fireplace until it is repaired. Gas units can be shut off at their valve while the repair is arranged.

Do you fit carbon monoxide alarms?

No. We record whether one is present and sounds when tested, and the owner or manager handles fitting or replacing it.

Our HOA owns the chimneys but owners own the fireplaces. Who books?

Whoever the governing documents make responsible for the part in question. The board often books the whole building so the records match, and each owner can receive their own unit page.

Can tenants stay home during the visit?

Yes. Each check takes a short time per unit, and we work around furniture and belongings. We need a clear path to the fireplace and a way into the unit.