Dennison Chimney Works

The code list for a fireplace, walked one item at a time

Ask for a code walkthrough

At the hearth: depth, width and the mantel

The floor in front of the opening must be noncombustible and must reach out far enough to catch a rolling log or a burst of sparks. The California Residential Code asks for at least 16 inches in front and 8 inches past each side for a smaller opening, and 20 and 12 inches once the opening passes 6 square feet. Many older hearths in Maywood fall short because a floor was raised or a hearth was trimmed during a past remodel.

Wood trim and mantels have their own rule. Nothing that can burn may sit within 6 inches of the opening, and trim within 12 inches may only project a small amount. When a homeowner wants a deep wood mantel, this rule sets its height. For factory-built fireplaces and inserts, the maker's manual sets the distances instead, and we work to those.

Inside: firebox, damper, smoke chamber and liner

NFPA 211 expects a flue that is sound, sized for what burns below it and free of gaps that let heat reach the house. A cracked clay tile, a missing section of liner or a smoke chamber with holes in its brick all fail that test. So does a gas insert or wood stove exhausting into an old masonry flue several sizes too big, which cools the exhaust and leaves it sluggish.

The usual fixes are relining with stainless steel sized to the appliance, parging the smoke chamber smooth and replacing broken firebrick. A damper that will not close or seal gets repaired or swapped for one that seals at the top of the flue.

  • Liner sized to the appliance's outlet
  • No gaps between flue sections
  • Smoke chamber walls whole
  • Firebox brick and joints intact

Through the house: clearance to framing

A masonry chimney inside the walls must stand clear of wood framing, by 2 inches inside the house and 1 inch where it runs along an outside wall, with the gap closed off by a noncombustible fire stop. In the attic we look for joists and boards laid tight against the brick, which was common practice when many local houses were built. Correcting it means cutting back the wood and firestopping the gap.

At the top: height, crown and cap

Under the code a chimney must rise a minimum of 3 feet past its roof penetration and clear by 2 feet anything within 10 feet of it, so the draft is not disturbed. The crown should shed water away from the flue, and a cap with a spark screen keeps rain and animals out and embers in. Leak work on the stack carries the prices below. Caps are quoted after we measure. Crown rebuilding, liners and clearance corrections get their own written figure.

In Maywood, wood fires also fall under the South Coast air district. Its Rule 445 bans burning wood on declared curtailment days, which is one reason many owners bring an old wood fireplace up to standard by fitting a gas insert instead.

Prices for the usual code fixes

These items come up again and again on a code list. Each price covers the work installed; the range depends on the size and access of your chimney. The cap is the exception: we quote it after we measure the flue.

Camera inspection to start the code list
$405
Finding and stopping water at the stack
$575 to $3,450
Diverter on the uphill side of the stack
$460 to $1,040
Diverter built with a new roof seal round it
$695 to $1,700
Gas firebox in place of the wood fire
$2,850 to $5,750
Screened cap for the flue top
Quoted after we measure

Crowns, liners, dampers, chase covers, flashing on its own and clearance corrections are measured first and given a written figure.

Code questions we hear

Does an older fireplace have to meet today's code?

Not every rule applies backward to an old house that is left alone. Changes are what bring the code in: a remodel, a new insert, a reline or a city permit for related work. Safety items such as a cracked flue or wood touching the brick are worth fixing either way.

Our new mantel looks too close to the opening. What now?

We measure it against the distances above or the maker's manual for your unit. Often the fix is raising the mantel or swapping the lowest trim for stone or tile, not removing the whole design.

Is a cap required?

A screened cap is the standard way to keep sparks in and weather out, and many inspectors ask for one. On factory-built chimneys the maker's own cap is part of the listed system and should be the one fitted.

Do we need a permit for these repairs?

It depends on the work and the city. Gas line work and new inserts usually involve one; minor masonry repair often does not. We say which items are likely to need a permit when we write the figure.

Can the work be split up?

Yes. We list the items that affect safety first and the rest after, each with its own line, so they can be scheduled as the budget allows.

Bring the fireplace up to standard

Use the contact page to tell us which code items were flagged and what kind of fireplace you have. We set a visit and list each item with its fix.

Call (323) 524-3963
Call (323) 524-3963